ESTIMATION OF RADIATION DOSE AND ORGANS AT RISK (OAR) ON ABDOMINAL CT-SCAN USING SIZE-SPECIFIC DOSE ESTIMATES (SSDE) METHOD
Authors
Kamelin Diah Sari , Gusti Ngurah Sutapa , I Gde Antha Kasmawan , I Nengah Sandi , I Nengah Artawan , Ni Luh Putu Trisnawati , I Komang WidianaDOI:
10.29303/ipr.v6i3.265Published:
2023-09-28Issue:
Vol. 6 No. 3 (2023)Keywords:
SSDE; DE; CT-scan; AbdomenArticles
Downloads
How to Cite
Abstract
A study has been carried out on the estimation of radiation dose and Organs at Risk (OAR) on abdominal CT-Scan examination using the SSDE method. The data used in this study were secondary data from medical records such as CTDIVol, DLP, and abdominal images of patients. This study aims to determine the size of SSDE, DE, and DEOAR and to determine whether DE is still within tolerance limits to ensure the feasibility of using CT-Scans in these installations. The SSDE value is obtained by multiplying the converted def value (f) and the CTDIVol, while the DE value is obtained by multiplying the DLP value and the conversion factor (k), finally, the DEOAR value is obtained by multiplying the CTDIVol and the organ/tissue weight factor. The results showed that the patient's average SSDE score was 12.04 ± 1.06 mGy, with a male SSDE value of 12.55 ± 1.30 mGy and a female SSDE value of 12.38 ± 2.47. While the average patient DEOAR value obtained was 7.57 ± 0.72 mGy and the patient's average DEOAR value for skin and bone surface was 0.09 ± 0.01 and red bone marrow and large intestine was 1.06 ±0.13. The DE value of this study is still below the tolerance value set by BAPETEN, which is less than 17.46 mGy.References
Asriwati, “Fisika Radiasi,” in Fisika Kesehatan dalam Keperawatan, 1st ed.Yogyakarta: Deepublish, 2017, pp. 166–168.
Rudi, Pratiwi, and Susilo, “PENGUKURAN PAPARAN RADIASI PESAWAT SINAR-X DI INSTALASI RADIODIAGNOSTIK UNTUK PROTEKSI RADIAS,” Unnes Physics Journal, vol. 1, no. 1, pp. 20–24, 2012,
M. Akhadi, “PENINGKATAN KESELAMATAN RADIOLOGIS DALAM KEGIATAN MEDIS,” Prosiding Pertemuan dan Presentasi Ilmiah Fungsional Pengembangan Teknologi Nuklir III, pp. 1–17, Dec. 2008,
H. A. Sianturi, M. Rianna, T. Sembiring, M. Situmorang, and J. Fisika, “Pengukuran dan Analisis Dosis Radiasi Keluaran pada Pesawat Sinar-X yang Berusia Lebih dari 10 Tahun pada Rumah Sakit di Kota Medan Measurement and Analysis of Output Radiation Dose on X-Ray Device over 10 Years at Hospitals in Medan City,” Journal of Aceh Physics Society, vol. 7, no. 1, pp. 1–5, 2018,
E. S. B. Siregar, G. N. Sutapa, and I. Wayan Balik Sudarsana, “Analisis Dosis Radiasi Pasien Pada Pemeriksaan CT Scan Menggunakan Aplikasi Si-INTAN Analysis of Radiation Dose of Patients on CT Scan Examination using Si-INTAN Application,” Buletin Fisika, vol. 21, no. 2, pp. 53–59, Aug. 2020,
P. G. A. K. Yogantara, G. N. Sutapa, and I. M. Yuliara, “Analisis Dosis Efektif Pada Pemeriksaan Computer Tomography (CT) Scan Kepala Di RSUD Sanjiwani Gianyar Effective Dose Analysis on Computer Tomography (CT) Head Scan at Gianyar Sanjiwani Hospital,” Buletin Fisika, vol. 22, no. 2, pp. 53–59, Aug. 2021.
H. Silvia, D. Milvita, H. Prasetio, and H. Yuliati, “ESTIMASI NILAI CTDI DAN DOSIS EFEKTIF PASIEN BAGIAN HEAD, THORAX DAN ABDOMEN HASIL PEMERIKSAAN CT-SCAN MEREK PHILIPS BRILIANCE 6,” Jurnal Fisika Unand, vol. 2, no. 2, pp. 128–134, 2013, Accessed: Jun. 14, 2023.
D. Suryani, “ANALISIS GELOMBANG ELEKTROMAGNETIK (SINAR-X) DALAM KESEHATAN PERSPEKTIF AL-QUR’AN DAN SAINS,” PROSIDING Seminar Nasional PendidikanFisika FITK UNSIQ, vol. 1, no. 1, pp. 115–120, 2018.
N. Wanara, M. Hamdi, and S. Sinuraya, “ESTIMASI NILAI DOSIS RADIASI EFEKTIF PASIEN DARI CITRA MEDIS CT SCAN ASTEION MULTI 32 SLICE BAGIAN ABDOMEN,” Komunikasi Fisika Indonesia (KFI), vol. 17, no. 2, pp. 80–86, Jul. 2020.
R. S. Masuku, “Analisis nilai Computer Tomography Dose Index(CTDI) dan Dose Length Product(DLP) pada pemeriksaan Multislice Computed Tomography(MSCT) trauma kepala dewasa di instalasi radiologi Rumah Sakit Balimed Denpasar, Bali,” Nautical : Jurnal Ilmiah Multidisiplin, vol. 1, no. 10, pp. 1235–1243, Jan. 2023, Accessed: Jun. 14, 2023.
Rusmanto and I. Syafitri, “PEDOMAN TEKNIS PENYUSUNAN TINGKAT PANDUAN DIAGNOSTIK ATAU DIAGNOSTIC REFERENCE LEVEL (DRL) NASIONAL,” Jakarta, Feb. 2016.
L. Sofiana, J. A. E. Noor, and I. Normahayu, “Estimasi Dosis Efektif Pada Pemeriksaan Multi Slice Ct-scan Kepala Dan Abdomen Berdasarkan Rekomendasi Icrp 103,” Brawijaya Physics Student Journal, vol. 1, no. 1, 2013, Accessed: Jun. 14, 2023.
J. M. Boone, K. J. Strauss, D. D. Cody, C. H. McCollough, M. F. McNitt-Gray, and T. L. Toth, “Size-specific Dose Estimates (SSDE) in Pediatric and Adult Body CT Examinations,” Alexandria, 2011. Accessed: Jun. 18, 2023.
J. A. E. Noor and I. Normahayu, “DOSIS RADIASI DARI TINDAKAN CT-SCAN KEPALA,” Journal of Environmental Engineering & Sustainable Technology (JEEST), vol. 1, no. 2, pp. 84–91, Nov. 2014.
C. McCollough et al., “The Measurement, Reporting, and Management of Radiation Dose in CT,” Alexandria, 2008. Accessed: Jun. 18, 2023.
J.-C. Nénot, J. Brenot, D. Laurier, A. Rannou, and D. Thierry, “Annexe B – Grandeurs utilisées en protection radiologique,” in Recommandations 2007 de la Commission internationale de protection radiologique, Paris: International Commission on Radiological Protection, 2007, p. 299. Accessed: Jun. 19, 2023.
I. H. Widjaja, “Dinding Abdomen,” in Anatomi Abdomen, 1st ed.Jakarta: Penerbit Buku Kedokteran EGC, 2009, p. 3.
T. R. Olson and W. Pawlina, “ABDOMEN,” in A.D.A.M. Student Atlas of Anatomy, Cambridge University Press, 2008, pp. 109–148.
License
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Authors who publish with Indonesian Physical Review Journal, agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution-ShareAlike 4.0 International Licence (CC BY SA-4.0). This license allows authors to use all articles, data sets, graphics, and appendices in data mining applications, search engines, web sites, blogs, and other platforms by providing an appropriate reference. The journal allows the author(s) to hold the copyright without restrictions and will retain publishing rights without restrictions.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in Indonesian Physical Review Journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).