DETERMINATION OF HALF AND TENTH VALUE LAYER PRIMARY AND SECONDARY WALLS OF X-RAY ROOM IN BALI JIMBARAN GENERAL HOSPITAL
DOI:
10.29303/ipr.v6i3.250Downloads
Abstract
The research has been carried out on the HVL and TVL values ​​of the primary and secondary walls of the radiology installation radiology room at RSU Bali Jimbaran. The aims of this study were (1) to determine HVL and TVL values ​​on the primary and secondary walls in the x-ray room, (2) to determine the differences between HVL and TVL values ​​if the tube voltages are varied. In determining the HVL and TVL values, ​​the linear attenuation coefficient of the walls must be known. The linear attenuation coefficient was determined by measuring the wall thickness by using a caliper, and measuring the radiation dose rate before and after passing through the primary and secondary walls. The results of the analysis of the HVL and TVL values ​​on the primary wall were 1.668 cm and 5.540 cm, meanwhile on the secondary wall ​​were 1.915 cm and 6.362 cm. When the voltage was varied 40 kV, 50 kV, 60 kV and 70 kV, there was no difference in the HVL or TVL values. Based on the results of the analysis, the HVL and TVL values ​​on the primary and secondary walls have a significant average difference.
Keywords:
HVL TVL linear attenuation coefficient radiation dose rate X-rayReferences
I. Septiyanti, M.A. Khalif and E.D. Anwar, “Analisis Dosis Paparan Radiasi Pada General X-ray II di Instalasi Radiologi Rumah Sakit Muhammadiyah Semarang,†Jurnal Imejing Diagnostik, vol.6(2), pp. 96-102, 2020.
K. Miniati, G.N. Sutapa, I.W.B. Sudarsana, “Uji Kelayakan Pesawat Sinar-X Terhadap Proyeksi PA (Postero-Anterior) dan LAT (Lateral) Pada Teknik Pemeriksaan Foto Thorax,†BULETIN FISIKA, vol.18, no.1, pp. 27-31, 2017. [Online]. Available: https://ojs.unud.ac.id/index.php/buletinfisika/article/view/31557. [Accessed June 8, 2023]
N.P.P.A. Yulianti, G.N. Sutapa and K.Y. Astina, “Uji Kesesuaian Kualitas Berkas Sinar-X Menggunakan Half Value Layer (HVL) Filter Aluminium Pada Pesawat Sinar-X Stationary di Akademik Teknik Radiodiagnostik dan Radioterapi Bali,†BULETIN FISIKA, vol.24(1), pp.27-31, February 2023. [Online]. Available: https://doi.org/10.24843/BF.2023.v24.i01.p04. [Accessed June 10, 2023]
I.L. Dewi and R. Dinanda, “Efek Paparan Radiasi dari Mesin X-Ray dan Metal Detector terhadap Kesehatan Petugas Pengamanan Lembaga Pemasyarakatan,†Journal of Correctional Issues, vol.3(1), 16-26, April 2020. [Online]. Available: https://doi.org/10.52472/jci.v3i1.42. [Accessed June 12, 2023]
D.R., Martem, D. Milvit, H. Yuliati, and D.D. Kusumawati, “Pengukuran Dosis Radiasi Ruangan Radiologi II Rumah Sakit Gigi dan Mulut (RSGM) Baiturrahmah Padang Menggunakan Surveymeter Unfors-XI,†Jurnal Fisika Unand, vol.4(4), pp. 414-418, 2015.
Hiswara, E. “Ketentuan Umum Proteksi dan Keselamatan Radiasi†in Buku Pintar Proteksi dan Keselamatan Radiasi di Rumah Sakit, Jakarta: BRIN, 2023, pp. 31-36. [Online]. Available: https://doi.org/10.55981/brin.579. [Accessed June 18, 2023]
S. Ramadhani, D. Milvita, H. Prasetio, and Mursiyatun, “Estimasi Laju Dosis Radiasi yang Lolos Melalui Dinding Primer dan Sekunder Berdasarkan Beban Kerja Pesawat Teleterapi Co-60 di Instalasi Radioterapi RSUP. Dr. M. Djamil Padang (Studi Kasus Januari- Juni 2019),†Jurnal Fisika Unand (JFU), vol.9(3), 284-291, July 2020. [Online]. Available: https://doi.org/10.25077/jfu.9.3.284-291.2020. [Accessed June 30, 2023]
Kristiyanti and B. Santoso, Penentuan Tebal Lead Glass Sebagai Bahan Perisai Radiasi Operator Pesawat Sinar-X Mamografi, Prosiding Seminar Penelitian dan Pengelolaan Perangkat Nuklir Pusat Teknologi Akselerator dan Proses Bahan, September 11, 2013 Yogyakarta : BATAN.
A. Yanyah, and H. Sutanto, “Penentuan Nilai Koefisien Serapan Bahan dan Dosis Radiasi pada Variasi Kombinasi Kayu dan Aluminium,†Youngster Physics Journal, Vol.4 (1) : pp. 87-92. January 2015.
F.H. Omoumi, X. Wu, M.U. Ghani, M.D. Wong, Y. Li, H. Liu, “Mathematical Estimation of Half Value Layer Thicknesses,†Journal of Applied Clinical Medical Physics, vol.22(10), 320-328, 2021. [Online]. Available: https://doi.org/10.1002/acm2.13385. [Accessed July 20, 2023]
P.S. Dahinde, G.P Dapke, S.D Raut, R.R Bhosale, P.P Pawar, “Analysis of Half Value Layer (HVL), Tenth Value Layer and Mean Free Path (MFP) of Some Oxidies in the Enerdy Range pf 122 KeV to 1330 KeV,†Indian Journal of Scientific Research, vol 9 (2), pp 79-84, January 2019.
M. Yunus, A. Amir, Mirnawati, Fitriani, S. Fatimah, “Compliance Test of X-ray Beam Quality Using HVL Parameter on Digital Mammography,†Journal of Technology, vol. 3(1), pp. 26-30, May 2022. [Online]. Available: https://doi.org/10.59563/djtech.v3i1.146. [Accessed July 21]
R. Aryawijayanti, Susilo, Sutikno, “Analisis Dampak Radiasi Sinar-X pada Mencit Melalui Pemetaan Dosis Radiasi di Laboratorium Fisika Medik,†Jurnal MIPA, vol.38(1), pp. 25-30, 2015.
R. Filano, E. Hidayanto, dan Z. Arifin, “Analisa Tingkat Kontaminasi Dosis Nuklir dan Laju Paparan Radiasi pada Instalasi Kedokteran Nuklir,†Youngster Physics Journal, vol.3(4), pp.317-328, 2014.
A. Akass, “Determination of the Tenth dan Half Value Layer Thickness of Concretes with Different Densities,†Journal International Science Congress, vol.129(4), 770-772, 2016. [Online]. Available: 10.12693/APhysPolA.129.770. [Accessed July 20, 2023]
License

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Authors who publish with Indonesian Physical Review Journal, agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution-ShareAlike 4.0 International Licence (CC BY SA-4.0). This license allows authors to use all articles, data sets, graphics, and appendices in data mining applications, search engines, web sites, blogs, and other platforms by providing an appropriate reference. The journal allows the author(s) to hold the copyright without restrictions and will retain publishing rights without restrictions.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in Indonesian Physical Review Journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).