Vol. 6 No. 1 (2023)
Open Access
Peer Reviewed

ANALYSIS OF THE EFFECT OF THE X-RAY TUBE CURRENT ON UNIFORMITY IMAGE NOISE VALUES

Authors

Anastasya Jessning Gamalita Mberato Mberato , Ni Nyoman Ratini , I Made Yuliara , Rozi Irhas

DOI:

10.29303/ipr.v6i1.183

Downloads

Received: Aug 05, 2022
Accepted: Nov 30, 2022
Published: Dec 02, 2022

Abstract

This research aimed to evaluate the effects of the X-ray current tube on the uniformity value of CT image noise. This research used the CT images of Siemens head water phantom. The phantom was scanned with a Siemens Somatom Scope CT scanner for various current tubes (i.e., 180 mAs, 200 mAs, 220 mAs, 240 mAs, and 260 mAs) on tube voltage 110 kV, slice thickness 3 mm, and FOV 240 mm. The uniformity values in CT image noise were analyzed using the standard deviation value (SD). The SD was measured by the ROI process in 5 different locations, in the center and at 3 o'clock, 6 o'clock, 9 o'clock, and 12 o'clock on the images CT. Based on the result of a simple linear regression test using IBM SPSS ver 25, it was found that the current tube significantly affected the uniformity value of image noise (r2=0,9768, p<0,05). This result showed that increasing the current tube can reduce image noise uniformity. The highest image noise uniformity value was at a current at 180 mAs with 0,217 HU, and the lowest was at 260 mAs with 0,031 HU. This result also shows that all the values are less than 2 HU and still within the acceptable limit by the BAPETEN standard regulation.

Keywords:

Uniformity Image Noise; CT number; CT Scan; Water phantom

References

Hutami, I. A. P. A., Sutapa, G. N., & Paramarta, I. B. A. (2021). Analisis Analisis Pengaruh Slice Thickness Terhadap Kualitas Citra Pesawat CT Scan Di RSUD Bali Mandara. BULETIN FISIKA, 22(2), 77-83.

Khairunnisak, K., Milvita, D., & Sandy, K. Y. P. (2017). Uji Kesesuaian Pesawat CT–Scan 64 Slice Merek Philips di Instalasi Radiologi Rumah Sakit Universitas Andalas Padang Menggunakan Detektor Unfors Raysafe X2. Jurnal Fisika Unand, 6(4), 355-361. doi: https://doi.org/10.25077/jfu.6.4.355-361.2017

Almuslimiati, A., Milvita, D., & Prasetio, H. (2019). Analisis Nilai Noise dari Citra Pesawat CT-Scan pada Beberapa Rekonstruksi Kernel dengan Variasi Slice Thickness. Jurnal Fisika Unand, 8(1), 57-63. doi: https://doi.org/10.25077/jfu.8.1.57-63.2019

Contillo,A.,Veronese,A.,Brombal,L.,Donato,S.,Rigon,L.,Taibi,A.,Tromba,G.,Longo,R. & Arfelli, F. (2018). A proposal for a quality control protocol in breast CT with synchrotron radiation. Radiology and Oncology,52(3) 329-336. doi: https://doi.org/10.2478/raon-2018-0015

Dewi, P. S., Ratini, N. N., & Trisnawati, N. L. P.(2022). Effect of x-ray tube voltage variation to value of contrast to noise ratio (CNR) on computed tomography (CT) Scan at RSUD Bali Mandara. International Journal of Physical Sciences Engineering, 6(2), 82–90. https://doi.org/10.53730/ijpse.v6n2.9656

S., A. A., Setiabudi, W., & Anam, C. (2015). Pengaruh Perubahan Tegangan Tabung (kVp) Terhadap CT Number dan Uniformitasnya pada Pesawat CT Scan. JURNAL SAINS DAN MATEMATIKA, 20(3), 77-80.

Mas' uul, A. R. I., & Sutanto, H. (2014). Uji Kesesuaian Ct Number Pada Pesawat Ct-Scan Multi Slice Di Unit Radiologi Rumah Sakit Islam YOGYAKARTA Pdhi. Youngster Physics Journal, 3(4), 335-340.

Alshipli, M., & Kabir, N. A. (2017, May). Effect of slice thickness on image noise and diagnostic content of single-source-dual energy computed tomography. In Journal of Physics: Conference Series (Vol. 851, No. 1, p. 012005). IOP Publishing.

Kalra, M. K., Maher, M. M., Toth, T. L., Hamberg, L. M., Blake, M. A., Shepard, J. A., & Saini, S. (2004). Strategies for CT radiation dose optimization. Radiology, 230(3), 619-628. doi: https://doi.org/10.1148/radiol.23030217266

Riyanto, S., Budi, W. S., & Anam, C. (2019). Pengaruh arus tabung terhadap noise dan kontras citra pada pesawat CT Scan. Berkala Fisika, 22(3), 105-109.

Prastanti, A. D., Cholid, B., & Jeffri, A. Optimalisasi Kejelasan Anatomi dan Dosis Radiasi Pada CT Scan Tulang Wajah (Maxillofacial) Dengan Variasi Kuat Arus Tabung. DEWAN REDAKSI, 10.

Irsal, M., & Winarno, G. (2020). Pengaruh Parameter Milliampere-Second (mAs) terhadap Kualitas Citra Dan Dosis Radiasi Pada Pemeriksaan CT scan Kepala Pediatrik. Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat, 17(1), 1-8.

Zhou, Y., Scott, A., Allahverdian, J., Lee, C., Kightlinger, B., Azizyan, A., & Miller, J. (2015). On the relationship of minimum detectable contrast to dose and lesion size in abdominal CT. Physics in Medicine & Biology, 60(19), 7671. doi: https://doi.org/10.1088/0031-9155/60/19/7671

Author Biographies

Anastasya Jessning Gamalita Mberato Mberato, Udayana

Ni Nyoman Ratini, Udayana University

I Made Yuliara, Udayana University

Downloads

Download data is not yet available.

How to Cite

Mberato, A. J. G. M., Ratini, N. N. ., Yuliara, I. M., & Irhas, R. (2022). ANALYSIS OF THE EFFECT OF THE X-RAY TUBE CURRENT ON UNIFORMITY IMAGE NOISE VALUES. Indonesian Physical Review, 6(1), 11–19. https://doi.org/10.29303/ipr.v6i1.183

Similar Articles

<< < 1 2 3 4 5 6 > >> 

You may also start an advanced similarity search for this article.